NX7
- Библиотека дву-/трехмерных CAD рисунков
- NX7_ NX7-series Machine Controller Спецификация
- Инструмент выбора продуктов
Thank you for downloading the NX7_ NX7-series Machine Controller Спецификация
Download againDid you know that 4 out of 5 distributors buy this product in a bundle?
There are many variations of passages of Lorem Ipsum available, but the majority have suffered alteration in some form, by injected humour, or randomised words which don't look even slightly believable.

-
Artificial Intelligence Demonstration - AI on the machine level
-
Artificial Intelligence Demonstration - AI on the machine level
An AI Controller is a unique tool that can bring data processing a step further, down to the end device. It operates deep in the heart of the machine itself to prevent a machine shutdown and to reduce error rates. To demonstrate the capability of an AI controller to react on disturbances, we simulate a filling process on a beverage production line. AI can also be used to make line changeovers very quick and easy, in a few seconds.
03:08
-
Контроллер Sysmac – серия NX7
Контроллер серии NX7 представляет собой высокопроизводительный ЦПУ, который включает в себя два синхронизированных ядра управления движением для управления до 256 осей.
- Минимальное время цикла управления: 125 мкс
- Количество осей: 256, 128
- Два синхронизированных ядра управления движением
- Функции: логическое управление, подключение к базам данных, искусственный интеллект и управление движением
- Прямое подключение к базам данных: клиент SQL для Microsoft SQL Server, Oracle, IBM DB2, MySQL, Firebird, PostgreSQL
- Прямое подключение к базам данных расширено в версии V2.0 за счет вызова хранимых процедур и функций защищенной связи
- Функциональность искусственного интеллекта: система искусственного интеллекта, интегрированная в контроллер, использует модель машинного обучения для обработки данных в режиме реального времени
- Библиотека AI Predictive Maintenance ("Предиктивное обслуживание на базе ИИ") обеспечивает бесперебойную работу оборудования
- Многозадачность
- Встроенные порты EtherCAT и два порта EtherNet/IP (1 Гбит/с)
- Поддержка топологии EtherCAT Ring для обеспечения связи и управления при обрыве кабеля или отказе устройства
Ordering information

Power supply units
Symbol | Description | Output capacity | RUN output | Order code |
---|---|---|---|---|
Total | ||||
100 to 240 VAC power supply unit for NX7 CPU | 90 W | Supported | NX-PA9001 | |
24 VDC power supply unit for NX7 CPU | 70 W | NX-PD7001 |
NX7 series CPU units
Symbol | CPU | Program capacity | Variables capacity | Power consumption | Functionalities | Number of axes | Order code | |||
---|---|---|---|---|---|---|---|---|---|---|
Sequence | Motion | DB connection | AI | |||||||
NX701 | 80 MB | 4 MB: Retained 256 MB: Not retained |
40 W | 256 | NX701-1720 | |||||
128 | NX701-1620 | |||||||||
256 | NX701-Z700 | |||||||||
128 | NX701-Z600 | |||||||||
256 | NX701-1700 | |||||||||
128 | NX701-1600 |
The end cover unit NX-END01 is included with the CPU unit.
EtherCAT junction slave
Symbol | Appearance | Name | No. of ports | Power supply voltage | Current consumption (A) | Dimensions (W x D x H) | Weight | Order code |
---|---|---|---|---|---|---|---|---|
![]() |
EtherCAT junction slave | 3 | 20.4 to 28.8 VDC (24 VDC –15 to 20%) |
0.08 | 25 mm × 78 mm × 90 mm | 165 g | GX-JC03 | |
![]() |
6 | 0.17 | 48 mm × 78 mm × 90 mm | 220 g | GX-JC06 |
- Please do not connect EtherCAT junction slave with OMRON position control unit, Model CJ1W-NC_81/_82.
- EtherCAT junction slave cannot be used for Ethernet/IP and Ethernet.
Industrial switching hub
Symbol | Appearance | Specifications | Accessories | Current consumption (A) | Order code | ||
---|---|---|---|---|---|---|---|
Functions | No. of ports | Failure detection | |||||
![]() |
Quality of Service (QoS): EtherNet/IP control data priority. Failure detection: Broadcast storm and LSI error detection 10/100 BASE-TX, Auto-Negotiation |
3 | No | Power supply connector | 0.22 | W4S1-03B | |
5 | No | W4S1-05B | |||||
5 | Yes | Power supply connector and connector for informing error | W4S1-05C |
Recommended EtherCAT and EtherNet/IP communication cables
Symbol | Item | Manufacturer | Color | Cable length (m) | Order code | ||
---|---|---|---|---|---|---|---|
EtherCAT cable | Cat 5e, AWG22, 2-pair cableM12/Smartclick connectorsImproved shield for EtherCAT communications | Standard typeCable with connectors
on both ends(M12 straight/M12 straight)![]() |
OMRON | Black | 0.5 | XS5W-T421-BM2-SS | |
1 | XS5W-T421-CM2-SS | ||||||
2 | XS5W-T421-DM2-SS | ||||||
3 | XS5W-T421-EM2-SS | ||||||
5 | XS5W-T421-GM2-SS | ||||||
10 | XS5W-T421-JM2-SS | ||||||
Rugged typeCable with connectors
on both ends(M12 straight/RJ45)![]() |
Black | 0.5 | XS5W-T421-BMCSS | ||||
1 | XS5W-T421-CMC-SS | ||||||
2 | XS5W-T421-DMC-SS | ||||||
3 | XS5W-T421-EMC-SS | ||||||
5 | XS5W-T421-GMC-SS | ||||||
10 | XS5W-T421-JMC-SS | ||||||
Ethernet/EtherCAT patch cable | Cat 6a, AWG27, 4-pair cableCable sheath
material: LSZH
2
,The lineup features low smoke
zero halogen cables for in-cabinet use and PUR cables for out-of-cabinet
use.
2
This cable is available in yellow, green
and blue colors. |
Standard typeCable with connectors
on both ends (RJ45/RJ45)![]() |
Yellow | 0.2 | XS6W-6LSZH8SS20CM-Y | ||
0.3 | XS6W-6LSZH8SS30CM-Y | ||||||
0.5 | XS6W-6LSZH8SS50CM-Y | ||||||
1 | XS6W-6LSZH8SS100CM-Y | ||||||
1.5 | XS6W-6LSZH8SS150CM-Y | ||||||
2 | XS6W-6LSZH8SS200CM-Y | ||||||
3 | XS6W-6LSZH8SS300CM-Y | ||||||
5 | XS6W-6LSZH8SS500CM-Y | ||||||
7.5 | XS6W-6LSZH8SS750CM-Y | ||||||
10 | XS6W-6LSZH8SS1000CM-Y | ||||||
15 | XS6W-6LSZH8SS1500CM-Y | ||||||
20 | XS6W-6LSZH8SS2000CM-Y | ||||||
Green | 0.2 | XS6W-6LSZH8SS20CM-G | |||||
0.3 | XS6W-6LSZH8SS30CM-G | ||||||
0.5 | XS6W-6LSZH8SS50CM-G | ||||||
1 | XS6W-6LSZH8SS100CM-G | ||||||
1.5 | XS6W-6LSZH8SS150CM-G | ||||||
2 | XS6W-6LSZH8SS200CM-G | ||||||
3 | XS6W-6LSZH8SS300CM-G | ||||||
5 | XS6W-6LSZH8SS500CM-G | ||||||
7.5 | XS6W-6LSZH8SS750CM-G | ||||||
10 | XS6W-6LSZH8SS1000CM-G | ||||||
15 | XS6W-6LSZH8SS1500CM-G | ||||||
20 | XS6W-6LSZH8SS2000CM-G | ||||||
Ethernet/EtherCAT patch cable | Cat 5e, AWG26, 4-pair cableCable sheath
material: PUR
2
The lineup features low smoke
zero halogen cables for in-cabinet use and PUR cables for out-of-cabinet
use. |
Standard typeCable with connectors
on both ends (RJ45/RJ45)![]() |
OMRON | Green | 0.5 | XS6W-5PUR8SS50CM-G | |
1 | XS6W-5PUR8SS100CM-G | ||||||
1.5 | XS6W-5PUR8SS150CM-G | ||||||
2 | XS6W-5PUR8SS200CM-G | ||||||
3 | XS6W-5PUR8SS300CM-G | ||||||
5 | XS6W-5PUR8SS500CM-G | ||||||
7.5 | XS6W-5PUR8SS750CM-G | ||||||
10 | XS6W-5PUR8SS1000CM-G | ||||||
15 | XS6W-5PUR8SS1500CM-G | ||||||
20 | XS6W-5PUR8SS2000CM-G | ||||||
Cat 5e, AWG22, 2-pair cable | Rugged typeCable with connectors
on both ends (RJ45/RJ45)![]() |
Grey | 0.3 | XS5W-T421-AMD-K | |||
0.5 | XS5W-T421-BMD-K | ||||||
1 | XS5W-T421-CMD-K | ||||||
2 | XS5W-T421-DMD-K | ||||||
3 | XS5W-T421-EMD-K | ||||||
5 | XS5W-T421-GMD-K | ||||||
10 | XS5W-T421-JMD-K | ||||||
15 | XS5W-T421-KMD-K | ||||||
Rugged typeCable with connectors
on both ends (M12 straight/RJ45)![]() |
Grey | 0.3 | XS5W-T421-AMC-K | ||||
0.5 | XS5W-T421-BMC-K | ||||||
1 | XS5W-T421-CMC-K | ||||||
2 | XS5W-T421-DMC-K | ||||||
3 | XS5W-T421-EMC-K | ||||||
5 | XS5W-T421-GMC-K | ||||||
10 | XS5W-T421-JMC-K | ||||||
15 | XS5W-T421-KMC-K | ||||||
Cat 5e, AWG22, 2-pair cable | Rugged typeCable with connectors
on both ends (M12 L right angle/RJ45)![]() |
Grey | 0.3 | XS5W-T422-AMC-K | |||
0.5 | XS5W-T422-BMC-K | ||||||
1 | XS5W-T422-CMC-K | ||||||
2 | XS5W-T422-DMC-K | ||||||
3 | XS5W-T422-EMC-K | ||||||
5 | XS5W-T422-GMC-K | ||||||
10 | XS5W-T422-JMC-K | ||||||
15 | XS5W-T422-KMC-K | ||||||
Ethernet installation cable | Cat 5, SF/UTP, 4 × 2 × AWG 24/1 (solid core), Polyurethane (PUR) | Weidmüller | Green | 100 | WM IE-5IC4x2xAWG24/1-PUR | ||
Cat 5, SF/UTP, 4 × 2 × AWG 26/7 (stranded core), Polyurethane (PUR) | Green | 100 | WM IE-5IC4x2xAWG26/7-PUR | ||||
Connectors | RJ45 metallic connectorFor AWG22 to AWG26 | ![]() |
– | – | WM IE-T0-RJ45-FH-BK | ||
RJ45 plastic connectorFor AWG22 to AWG24 | ![]() |
OMRON | – | – | XS6G-T421-1 | ||
RJ45 socket | DIN-rail mount socket to terminate installation cable in the -cabinet | Weidmüller | – | – | WM IE-T0-RJ45-FJ-B |
Please be careful while cable processing, for EtherCAT, connectors on both ends should be shield connected and for EtherNet/IP, connectors on only one end should be shield connected.
WE70 FA wireless LAN units
Appearance | Name | Area | Type | Order code |
---|---|---|---|---|
![]() |
WE70 FA wireless LAN units | Europe | Access point (Master) | WE70-AP-EU |
Client (Slave) | WE70-CL-EU | |||
Directional magnetic-base antenna | 1 set with two antennas, 2.4 GHz/5 GHz Dual-band compatible | WE70-AT001H | ||
DIN rail mounting bracket | For TH35 7.5 | WT30-FT001 | ||
For TH35 15 | WT30-FT002 | |||
Antenna extension cable | 5 m | WE70-CA5M |
Special versions are available for USA, Canada, China and Japan.
Accessories
Appearance | Specifications | Order code | |
---|---|---|---|
![]() |
SD memory card | 2 GB | HMC-SD291 |
4 GB | HMC-SD491 | ||
![]() |
DIN track | Length: 0.5 m; height: 7.3 mm | PFP-50N |
Length: 1 m; height: 7.3 mm | PFP-100N | ||
Length: 1 m; height: 16 mm | PFP-100N2 | ||
![]() |
Battery for NX7/NJ CPU unit (The battery is included with the CPU unit) | CJ1W-BAT01 | |
![]() |
End cover (The end cover is included with the CPU unit. Necessary to be connected to the right end of the CPU rack) | NX-END01 | |
Fan unit (The fan unit is included with the CPU unit) | NX-FAN01 |
Computer software
Specifications | Order code | ||
---|---|---|---|
Sysmac Studio
2
For the NX701-Z
CPU units (with Artificial Intelligence), Sysmac Studio version
1.25 or higher is needed. |
SYSMAC-SE2___
2
Refer
to the Sysmac Studio datasheet (https://industrial.omron.eu/en/products/sysmac-studio)
for detailed information or contact your OMRON representative. |
||
AI Controller Software | Software that provides an operation interface for AI programming | DVD | SYSMAC-AICSTE00D |
1 license | SYSMAC-AICSTE01L |
Stored procedure
Что такое хранимая процедура?
Хранимая процедура является одной из функций базы данных. Группа инструкций SQL хранится в базе данных, что позволяет выполнять сложную обработку одним вызовом. Функция вызова хранимой процедуры из базы данных контроллера добавлена в версию 2.0.

Безопасное соединение между FA и IT
Аутентификация на основе сертификатов сервера и шифровка данных связи обеспечивают безопасное соединение между сервером базы данных и ЦПУ.*1

Сбор данных выполняется в 5 раз быстрее, чем при использовании предыдущего метода
Пакетная вставка позволяет хранить различные типы данных в течение длительного времени, как и регистратор данных событий. Это позволяет определить причины остановки линии путем анализа данных, собираемых при каждом сканировании.*1*2

Автоматическое создание таблиц из структур и наоборот
Таблицу базы данных можно автоматически создать из структуры, а структуру можно автоматически создать из таблицы базы данных. Время отображения можно сократить.*1

1. Доступна в моделях NX701-1□20 и NX102-□□20. Скоро будет доступна в серии NJ□01-□□20.
2. По сравнению с выполнением нескольких вставок.
3. Для удаления таблиц требуется хранимая процедура.
Sysmac Studio

AI Controller Software

Библиотека программных компонентов AI Predictive Maintenance ("Предиктивное обслуживание на базе ИИ") рассчитывает оптимальные значения признаков на основе данных, получаемых от рабочего механизма, для оценки состояния производственного оборудования.

Мы интегрировали системы управления движением, системы безопасности, устройства ввода/вывода, системы технического зрения, системы измерения и датчики, а также средства визуализации в единую платформу Sysmac.
Рассмотрим полный ассортимент Sysmac.
Спецификации
Паспорт безопасности аккумуляторной батареи
Технические руководства
Показать все технические руководстваПодписаться на новости и обновления о продуктах
Подпишитесь на новостную рассылку и получайте новости о разработках продукции, решениях и услугах прямо на свой почтовый ящик.
Благодарим Вас за подписку на Omron eNews. В ближайшее время на электронный адрес, который Вы указали при регистрации, будет выслано уведомление о подтверждении подписки. Чтобы подтвердить подписку, проследуйте указанной в письме ссылке. Данная процедура необходима для соблюдения существующих правовых норм и в целях предотвращения возможного злоупотребления Вашим электронным адресом третьими лицами.
Возникли технические проблемы. Ваша форма не была отправлена. Примите наши извинения и повторите попытку позже. Детали: [details]
DownloadОбучающие курсы
Пройти обучающие курсы от наших лучших специалистов. От начального до продвинутого уровня.
Просмотреть обучающие курсы